AUPO Radial Lead Thermal Link Motor Thermal Cutoff Fuse 250V 3A Temperature Fuse Square Type

AUPO Radial Lead Thermal Link Motor Thermal Cutoff Fuse 250V 3A Temperature Fuse Square Type

Product Details:

Place of Origin: China
Brand Name: AUPO
Certification: UL VDE PSE CCC KTL
Model Number: AX-3A-F

Payment & Shipping Terms:

Minimum Order Quantity: 2000
Price: USD $0.05~$0.1 per piece
Packaging Details: 100pcs per bag, 10000pcs per carton
Delivery Time: 15 days
Payment Terms: T/T
Supply Ability: 50K pieces per month
Get Best Price Contact Now

Detail Information

Item Name: Thermal Fuse, Thermal Cutoff, Thermal Link Part No.: AX-3A-F
Voltage Rating: 250V Current Rating: 3A
Tf: 84~160 Degree Case Dimension: 6.2x6.3mm
Mounting Type: Radial Leaded Blow Type: One Shot Operation
Case Type: Plastic UL Listed: Yes
RoHS Compliant: Yes Halogen Free: Yes
MPQ: 100pcs MOQ: 2000pcs
Standard Lead Length: 70mm
Highlight:

3A 70mm Thermal Cutoff Fuse

,

UL 70mm Thermal Cutoff Fuse

,

70mm Thermal Cutoff Fuse

Product Description

AUPO Radial Lead Thermal Link Thermal Cutoff Fuse 250V 3A Temperature Fuse Square Type

Product Description

Item thermal fuse, thermal cutoff, thermal link
Body Tyle plastic
Lead Dia 0.6mm
Lead Length 70mm
Voltage Rating 250V ac
Current Rating 3A
Mounting Type   radial leaded
Body Size 6.2x6.3mm
Standards

IEC 60691 Ed4.0, GB/T 9816.2013

Certifications UL VDE PSE CCC KTL

 

Dimension

AUPO Radial Lead Thermal Link Motor Thermal Cutoff Fuse 250V 3A Temperature Fuse Square Type 0


Product Features

  • Rated Current: 250V 3A
  • Advantage: One shot operation
  • High sensitivity to ambient temperature
  • High accuracy and stability
  • Tiny structure
  • Excellent sealing structure

Specification

Model No a b c d e
A-3A-F 6.2±0.5 6.3±0.5 2.5±0.3 Φ0.6±0.02 70±3

 

Model NO. Tf(℃)

Fusing-off

Temperature(℃)

Th(℃) Tm(℃) Ir(A) Ur(V)
IEC Corp
A0-3A-F 84℃ 84 + 0 / -10 82±2 65 203 2 250
A1-3A-F 102℃ 102 + 0 / -10 98±2 80 203 2 250
A2-3A-F 115℃ 115 + 0 / -10 112±3 99 203 2 250
A3-3A-F 125℃ 125 + 0 / -10 120±3 105 203 2 250
A4-3A-F 130℃ 130 + 0 / -10 126±2 107 203 2 250
A5-3A-F 135℃ 135 + 0 / -10 131±3 115 203 2 250
A7-3A-F 138℃ 138 + 0 / -10 135±2 118 203 2 250
A12-3A-F 145℃ 145 + 0 / -10 140±2 126 203 2 250
A8-3A-F 150℃ 150 + 0 / -10 145±3 128 203 2 250
A16-3A-F 160℃ 160 + 0 / -10 155±2 140 203 2 250

Temperature Rating (Tf):Rated opening temperature

Holding temperature (Th):Maximum temperature measured at the case end ofthe thermal cutoff at which the thermal cutoff  can be maintained for a period for 168 hours without opening.

Maximum temperature (Tm):The maximum temperature at which a thermal cutoff can be maintained for10 minutes as an open circuit and can then be maintained at twice rated voltage for a period of 2 minutes during which its mechanical and electrical properties will not be impaired

 

Structure

AUPO Radial Lead Thermal Link Motor Thermal Cutoff Fuse 250V 3A Temperature Fuse Square Type 1

 

Applied to over-heat protection for all kinds of low-power motors, coils and etc.

APPLIANCES - space heaters, irons, stoves, electric blankets, hair dryers, clothes dryers, cookers,

toaster ovens,crock pots, mixers, toasters,microwave ovens, etc.

MOTORS - air conditioners,copiers, fans, washing machines, compressors,etc.

ELECTRONICS - TVs,stereos, tape recorders,video recorders, fluorescent lamps, transformers, computers, 

surge suppressors,telecommunication equipment, etc

 

Thermal Fuse Characteristics:
It consists of a sliding contact, a spring, and an electrically nonconductive thermal pellet.

Before the thermal fuse is activated, current flows from the left lead to the sliding contact

and through the metal housing to the right lead. When the external temperature reaches

a predetermined temperature, the organic matter meltsand the compression spring

becomes loose. That is, the spring expands and the sliding contact is separated from the
left lead. The circuit is opened and the current between the sliding contact and the left lead

is cut off.
 

Precautions When Using Thermal Cutoffs
The following information describes the correct methods of using thermal cutoffs to insure
proper and safe performance. To achieve the full use and capacity of a thermal cutoff, it is
necessary for the customer to exercise proper storage and execute appropriate circuit design,
proper installation, and adequate testing. Thermtrol Corporation does not assume responsibility
for problems which occur as a result of improper storage and installation, or inappropriate circuit
design, evaluations or tests.
• Do not use thermal cutoffs for purposes other than for what they are intended. Thermal cutoffs
operate only when they sense an ambient temperature greater than the factory pre-set temperature.
They have no ability to function by current overload and are not current limiting devices.
• Do not use thermal cutoffs in equipment, appliances or devices intended to be used in the
aerospace industry, aviation, nuclear power generation systems, life support systems, engine control
systems, or safety control systems for transportation. Thermal cutoffs are applicable for electrical
household devices, appliances and electronics. Other applications include: office automation equipment,
audiovisual equipment, communication systems, measuring instruments and specific transportation systems.
• Do not use thermal cutoffs in applications exceeding the listed ratings in the specification chart.
• Do not use thermal cutoffs in a liquid, in a corrosive atmosphere such as sulfurous gas, or in a high
humidity environment.
• Customers shall choose the thermal cutoff appropriate for the application and determine the proper
mounting position and/or method. To judge whether the selected thermal cutoff and chosen position
and method of mounting is suitable for the final application, we recommend that the customer fully test
and evaluate the unit in an environment that duplicates the final application as closely as possible.
This includes mounting and securing the thermal cutoff identically to the method that will be used in
production.
 

Standard Package

100pcs per bag, 10000pcs per carton

 

Shipping Term:

EXW, DDU, DDP, C&F, FOB

 

Shipping Methods:

International Express, By Air, By Sea

 

Test Equipment
  • AUPO Radial Lead Thermal Link Motor Thermal Cutoff Fuse 250V 3A Temperature Fuse Square Type 2
  • Company warehouse
  • AUPO Radial Lead Thermal Link Motor Thermal Cutoff Fuse 250V 3A Temperature Fuse Square Type 3
FAQ

Q: Are you trading company or manufacturer ?

A: We are a fuse product factory.

Q: How long is your delivery time?

A: Generally it is 3 days if the goods are in stock, 5-10 days if the goods not in stock, according to the quantity.

Q: Do you provide samples ? is it free or extra ?

A: Yes, we could offer the sample for free charge but do not pay the cost of freight.

Q: What is your terms of payment ?

A: 100% in advance, T/T.